Structural Design Errors: Common Causes and Prevention
Design errors may emerge owing to wrong assumptions, computational and analysis errors, modelling, detailing, coordinating, or lack of consideration of how the structure will be erected. The above-listed sources of errors do not have the same importance; some of them may be minor while others might seriously influence safety, performance, constructibility, and costs of the project if they remain undetected.
Early identification of the possible sources of errors is important due to the increasing costs and complexity involved in their correction. For example, identifying a wrong assumption during design review may require only minor actions, but detecting the same error during erection will entail redesigning, reworking, and delays. This article discusses the sources of errors, their typical types, and ways of detection and prevention.
What are Structural Design Errors?
Structural design errors are errors, mistakes, or wrong assumptions introduced anywhere in the process of structural design development, ranging from the information provided to an engineer to the way in which a design will be ultimately constructed on the site. Structural design errors may not necessarily come in the form of mathematical calculation mistakes; there are many other places where errors may creep into the process.
It is useful to understand that structural design is essentially a process that is sequential in nature such that a mistake that creeps into the process in one stage can persist throughout all the rest of the stages of the process as well:
Input → Analysis → Design → Detailing → Coordination → Construction
The illustrative flow above is not a prescribed standard sequence, but a simplified way of showing how information can pass through the design and delivery process. For a more formal project framework, IStructE provides a structural plan of work covering briefing, concept design, spatial coordination, technical design, construction, handover, and use.
Structural Design Error Causes
Structural design errors are not usually caused by just one factor; they usually arise due to a variety of factors, including inadequate information, false assumptions, and inadequacies in the verification process, and not because a particular engineer makes a careless mistake. This is because the knowledge of these root causes is far more important than knowing the types of errors. Below are common causes that lead to errors in structural design:
- Partial or incomplete information about the project – design-based drawings, specifications, or data that have not been completed or coordinated.
- Incorrect assumptions about any aspect of the design – including loading, material behaviour, supports, or the actual structural behaviour itself.
- Insufficient checking – inadequate review of the calculations or modelling process before it is used for the design.
- Late changes to the design – changes late in the design process which do not allow an adequate check against the existing design.
- Poor coordination – poor coordination between structural, architectural, or building services information which needs to be consistent.
- Incorrect interpretation of information – wrong reading of the data from site investigations, tests, or analysis results.
- Inappropriate structural model – the structural model does not sufficiently represent the actual structure.
- Insufficient allowance for the construction process – a design which works in theory but presents practical problems or difficulties during construction.
What are the Most Common Structural Design Errors?
Although there are numerous combinations of factors that could lead to errors, some error categories tend to be consistent throughout structural design. The following table lists these most common error categories, what causes them to happen, and how they can be prevented.
| Error category | Common problem | Cause | Prevention |
|---|---|---|---|
| Load Assumptions | Missing loads, incorrect data, or wrong combination. | Incomplete information about the project, or changes to occupancy without reassessment. | Always systematically check all related steps and combinations against project requirements. |
| Analysis and Calculation | Errors in mathematics, boundary conditions, or misinterpretation of output. | Insufficient independent review, or overly simplistic assumptions made at the detailed level. | Undertake independent checking and ask yourself whether the results make physical sense. |
| Structural Modelling | Wrong geometry, support systems, or stiffness assumptions. | A model which is no longer an adequate representation of the real behaviour of the structure, usually by being overly simplistic. | Check your model results against your manual calculations or anticipated behaviour. |
| Stability | Insufficient bracing, buckling, lateral stability, or overturning problems. | Stability considerations separated from members’ considerations, instead of considered together. | Check overall and individual stability as a separate design check. |
| Detailing and Connections | Problems with reinforcement, steel joints, bolts, welding, or anchorage. | A good overall approach but with incomplete details. | Check that every detail matches the reality of actual connection behaviour and site construction. |
| Foundation Design | Wrong choice of foundation type, bearing capacity, or settlements. | Use of inadequate or incomplete site investigation results. | Design foundations based on adequate site investigation for the particular project. |
| Coordination | Interference between structural/architectural/MEP data | Drawings/models/revisions not consistent between disciplines | Compare your models and drawings regularly, especially following design changes. |
What Problems Can Structural Design Errors Cause?
Detection of design mistakes is mainly a case of knowing how to look out for them during design reviews rather than using a specific method of design checking. Design errors tend to have some kind of trace, whether inconsistencies, assumptions not adequately documented, analysis results that do not make sense, or any other indicator that something is wrong if one is looking for them. In addition, it would be important to look out for the following items during design reviews:
- Inconsistent calculations with the actual drawings.
- Unexplained or unjustified assumptions.
- Unexpected results of the analysis.
- Incomplete load paths in the structure.
- Inconsistent dimensions between different drawings or models.
- Inconsistencies between the structural model and the drawings generated from it.
- Coordination problems with architectural or mechanical and electrical parts.
- Design information missing where it should be available.
- Design changes that have not been reviewed with respect to the existing design.
How to Prevent Structural Design Errors
The problem of avoiding any design faults requires a systematic approach to the task, and not just using one check that will find all potential faults. Each stage of the process is listed in the table below along with its importance in avoiding one type of fault.
| Step | Stage | Why It Matters |
|---|---|---|
| 1 | Verify project information | Detects any errors in the input data due to a lack of coordination before analysis and design. |
| 2 | Confirm loads and assumptions | Avoids having an invalid load input that may form the basis of the design. |
| 3 | Validate the structural model | Ensures the accuracy of the model in reflecting the true behaviour of the structure, and not a simplified version. |
| 4 | Check calculations and analysis | Detects any errors in arithmetic calculations, misinterpretations of results, and faulty assumptions. |
| 5 | Review stability | Verifies that both stability and that of the individual elements have been checked. |
| 6 | Check detailing and connections | Verifies that the details are practically buildable and not only theoretically possible. |
| 7 | Coordinate disciplines | Detects any conflicts between structural, architectural, and MEP data. |
| 8 | Consider construction sequence | Ensures that the design takes into account the construction process, and not only the end product. |
| 9 | Complete appropriate design checks | Verifies that all necessary checks have been done before the use of the design. |
Structural Design Errors Checklist
This checklist below is a compilation of all the review items discussed in this article into a concise guide that one can go through while conducting the design review, providing a focal point to each category instead of using just one generic checklist to ensure all problems in the entire design are captured.
Loads
Ensure that all actions that should be considered have not been overlooked, load values are correct, and combinations consider the worst possible scenario for the structure, rather than considering the load individually.
Analysis
Boundary conditions should be verified to make sure that they really describe the support of the structure, and results should be analysed to see if they behave accordingly.
Model
Verify that the assumptions concerning geometry, supports, and stiffness are truly representative of the actual structure, instead of a highly simplified one that does not adequately capture the behaviour.
Stability
Ensure that bracing, buckling, and lateral stability have been separately addressed, and not just considered alongside the strength of individual elements during the design process.
Detailing
Confirm that connections and reinforcements accurately model reality, and that each detail illustrated in the drawings is constructible.
Coordination
Look out for any conflict within the data related to the structure, architecture, and building services, especially in places where a change in the design has occurred recently.
Foundations
Make sure that the type of foundation, bearing capacity, and settlement have been established on adequate site investigation data rather than general assumptions.
Construction
Make sure that the design takes into account the method of constructing the structure rather than just looking at its final form.
Thoroughly used, these checks provide a structured way to identify inconsistencies before progressing into design or construction stages later. They are not for replacing project checking procedures, but to concentrate attention on common areas where structural design errors potentially arise.
Professionals who are looking to reinforce these skills through further study, it is worthwhile considering the course criteria to have the best option when choosing training programme that can be helpful for upskilling structural engineering competence.
Frequently Asked Questions
| What are the typical errors in structural design? There are several common categories, such as errors in load assumptions, errors in analysis and calculations, errors in modelling, stability errors, detailing and connection errors, errors in foundation design, and coordination between structural, architectural, and other building services data. |
| What leads to structural design errors? These errors usually happen due to lack of proper information, wrong assumptions, lack of checks, late design changes without additional checks, lack of discipline coordination, misunderstanding of data, wrong modelling, and lack of consideration for construction conditions. |
| How to prevent structural design errors? To prevent structural design errors, there is a step-by-step approach that includes checking of information, loads, and assumptions; the model, calculations, stability, detailing, discipline coordination, and consideration of the construction sequence. |
| What are the consequences of undetected errors in structural design? Undetected errors will result in redesign, rework, delay, extra cost, unresolved conflicts, poor structural performance, and even structural failure in severe cases, though most of them are detected much earlier. |
| How can structural design errors be detected? They are detected at the design review stage by detecting inconsistencies between calculations and drawings, unexplained assumptions, strange analysis results, incomplete load paths, inconsistent dimensions, coordination problems, lack of information, and unverified design modifications. |